Electrical equipment
- TRANSFORMER - HAMMOND - 500 VA - 600 to 120/240SKU 57065-42
TRANSFORMER, HAMMOND, 500 VA
Learn More
TYPE: H, CAT#: HL9P, STYLE: 2AH
PRIM : 600 VOLTS
SEC : 120/240 VOLTS
- TRANSFORMER - GENERAL ELECTRIC - 1 KVA - 240/480 to 120/240SKU 57066-42
TRANSFORMER, GENERAL ELECTRIC, 1 KVA
Learn More
MODEL: 9T51B10
VOLTAGE PRIM 240/480
VOLTAGE SECONDARY120/240
1 PH 60 HZ TYPE QB
- TRANSFORMER - HAMMOND - 3 KVA - 600 to 120/240SKU 57136-42
TRANSFORMER - HAMMOND 3 KVA - HV 600 - LV 120/240
Learn More
VOLTS: 600, RATED VOLTAGE: 100, CONNECTION: H1-H3
VOLTS: 585, RATED VOLTAGE: 97.5, CONNECTION: H1-H2
HV 600 - LV 120/240
3PH
CAT: FS9P
WEIGHT: 70 POUNDS
TYPE: ANN
TEMP RISE: DEG C: 150
TEMP CLASS: DEG C: 200 - TRANSFORMER - DELTA - 3 KVA - 600 to 120/240SKU 57112-42
TRANSFORMER - DELTA - 3 KVA - USED
Learn More
MODEL: DT 1003
PRIMARY: 600 VOLTS
SECONDARY: 120/240 VOLTS
PHASE: 1
ENCLOSURE: 1
SERIAL: 1484-1288
MADE IN: GRANBY, QC CANADA
WEIGHT: 24 LBS - TRANFORMER - G.E. - 15 KVA - 480 to 208Y/120SKU 59172-42
TRANFORMER, GENERAL ELECTRIC, 15 KVA
Learn More
HV: 480
LV: 208Y/120
3 PH
60 HZ
CAT#: 15M109 - TRANSFORMER - RELIANCE - 38.9 KVA - 480 to 480Y/270SKU 57934-42
TRANSFORMER, RELIANCE, 38.9 KVA
Learn More
DT3 TRANSFORMER
PRIMARY: 480
SECONDARY: 480Y/270
ZIG ZAG /227
3 PH
60 HZ
% IMP AT 170°C, 2.8
CAT#: BED1785
S/N: 71B712 - TRANSFORMER - RELIANCE - 53.2 KVA - 480 to 480Y/270SKU 57307-42
TRANSFORMER, RELIANCE DT-3, 53.2 KVA
Learn More
3 PH, CLASS H
504 V : 3 - 4
480 V : 3 - 5
456 V : 2 - 5
480Y
270
STYLE: BED 1786
S/N : 71B714
WEIGHT : 500 LBS
- TRANSFORMER - RELIANCE - 53.2 KVA - 480 to 480Y/270SKU 57308-42
TRANSFORMER, RELIANCE DT-3, 53.2 KVA
Learn More
504 V : 3 - 4
480 V : 3 - 5
456 V : 2 - 5
480Y
270
STYLE: BED 1786
S/N : 71B714
WEIGHT : 500 LBS - TRANSFORMER - RELIANCE - 63.2 KVA - 480 to 480Y/270SKU 57290-42
TRANSFORMER, RELIANCE, 63.2 KVA
Learn More
STYLE BED1822
PRIMARY: 480
SECONDARY: 480Y/270
504 V : 3 - 4
480 V : 3 - 5
456 V : 2 - 5
480Y
270
INSULATION CLASS: H - TRANSFORMER - RELIANCE - 75 KVA - 230/460 to 230YSKU 57259-42
TRANSFORMER, RELIANCE, 75 KVA
Learn More
HV: 230/460
LV: 230Y
3 PHASES
TYPE MBT
C-RISE: 80
SPEC #: 1-10126
S/N: 1803-1 - TRANSFORMER - RELIANCE - 75 KVA - 230/460 to 230SKU 57261-42
TRANSFORMER, RELIANCE, 75 KVA
Learn More
HV : 230/460
LV : 230Y
3 PHASES
TYPE: MBT
C-RISE: 80
SPEC #: 1-10126
S/N: 1803-2
MADE IN: CLEVELAND, OHIO, USA
- TRANSFORMER - RELIANCE - 82.7 KVA - 480 to 480YSKU 57935-42
TRANSFORMER, RELIANCE, 82.7 KVA
Learn More
PRIMARY: 504/480/456 VOLT
SECONDARY: 480Y/270 VOLT
60 HZ
3 PH
% IMP AT 170°C: 5.4
CAT#: BED1823
S/N: 71B722
WT 525 - TRANSFORMER - RELIANCE - 149 KVA - 480 to 480 ZIG ZAG /227SKU 57933-42
TRANSFORMER, RELIANCE, 149 KVA
Learn More
PRIMARY: 480 DELTA TAPPED
SECONDARY: 480 ZIG ZAG /227
TERT: 270-1
60 HZ
3 PHASES
150°C RISE
INSULATION CLASS: H
CAT# 13750, S/N: 26221 - TRANSFORMER - MARCUS - 400 KVA - 600 to 480SKU 24926-249
TRANSFORMER, MARCUS, 400 KVA
PRIM: 600 VOLTS
SEC: 460 VOLTS
3 PH
SERIAL #: 491-590
%IMP: 4.6
Temp. Rise: 150°C
Type: TWF
WEIGHT: 2550 LB*NO NEUTRAL (DELTA-DELTA)*
*24925-249: ALREADY SOLD*
Learn More - MOTOR - AC - MARATHON - 50 HP - 1800 RPM - 230/460 VOLTSSKU 14500-1016
MOTOR - AC - MARATHON BLUE MAX
INVERTED DUTY: VFD Rating CONSTANT 2000:1
50HP @ 90°C - HIGH TEMPERATURE APPLICATION
1775RPM
FRAME: 365T
460 VOLTS
ENCLOSURE: TOTALLY ENCLOSED BLOWER COOLED - AXIAL
SERVICE FACTOR: 1.0
INSULATION CLASS: H
3 PH, 60 HZ
DUTY: CONT.
DESIGN CODE: INV
KVA CODE: H
MODEL # : 365THFS8066AN W
SERIE WAA116994
MANUFACTURED IN 20184 AVAILABLE
Learn More - VOLTAGE SENSOR - CATU & PARIS - CL 1-05SKU 63143-42
VOLTAGE DETECTOR, CATU-PARIS, CL-36.07 CDN
Learn More
RANGE OPERATING: 2.4-36 KV
TEST VOLTAGE: 75KV
PIEZ O TEST Separate testing device for phase comparator
Piezo-electric generator activated via a handle mechanism
providing a high frequency voltage.
Metal contact at the tip of the device. This contact may receive
the “banana” plug of the extension lead to facilitate testing on
very long detectors.
Earth socket at the base of the unit receiving a plug for making
closed-circuit tests.